iSF6-1800S SF6 Multi Analyzer

Measure dew point, purity, decomposition byproducts of SF6 and pressure for electric equipment filled with SF6 gas.

iSF6-1800S multi analyzer can be used in GIS switches and other SF6 high-voltage insulated switchgear or divices, which filled with SF6 gas, to detect the moisture content, purity, decomposition products and chamber’s gas pressure. The analyzer is equipped with a unique gas processing system, which can recover and store the measured sample gas into the gas tank inside the instrument, and can pump the sample gas back to the gas chamber or container after the test, to achieve zero emission of SF6 sample gas.

The moisture detection of the iSF6-1800S adopts the classic cold mirror detection technology to improve the accuracy, stability, and reliability of long-term use. The purity of SF6 is detected by NDIR infrared optical technology, which can meet the higher requirements of purity detection for switching equipment. In addition, the instrument is equipped with a constant control system of pressure and flow to further ensure the accuracy and stability of the data in the detection of each function.

iSF6-1800S is the first choice in the market for SF6 gas measurement for it integrates advanced technologies and concepts and meets the requirements of users on environmental protection, functionality, accuracy, data processing, and human-machine interaction.

Key Features

 
  • SF6 zero emission
  • Mirror dew point technology
  • Non-dispersed Infrared (NDIR) technology
  • High precision flow control
  • Built-in recovery and pumping system
  • One-key start operation
  • Large capacity data storage
  • Pressure and temperature compensation
  • Self-sealing coupling
  • Multi-language selection
  • TFT true color touch screen
  • Overload protection

 

Specification

Moisture content
range: -60 ℃~+20 ℃
humidity content by volume: 11~20,000 ppmv
humidity content by weight: 1.3~2,500 ppmw
accuracy: ≤±0.2℃ (Continuous measuring mode)
≤±0.5℃(Auto measuring mode)
ppmv /ppmw: ≤±1ppm+6% of reading
resolution: ±0.01℃

Purity
range: 0~100 %
accuracy:≤ ±0.5%
resolution: 0.01%

Decomposition Products(Optional)
SO2  range: 0~20 ppmv
accuracy: ≤±2% F.S.
SO2  range: 0~100 ppmv
accuracy: ≤±2% F.S.
SO2  range:0~500 ppmv
accuracy: ≤±2% F.S.
HF  range:0~10 ppmv
accuracy: ≤±3% F.S.
H2S  range:0~100 ppmv
accuracy: ≤±3% F.S.
CO  range:0~1000 ppmv
accuracy: ≤±4% F.S.
CF4  range:0~5000ppmv
accuracy: ≤±2% F.S.
CF4  range: 0~100%
accuracy: ≤±1% F.S.

Pressure: 1~11 bar abs.
Flow rate: 255~600 ml/min
Working condition: 0 ℃~+40 ℃ 10~90% @40℃, non-condensing
Mains power:  100~240 VAC 50/60 Hz
Dimension:  629 × 497 × 353 mm
Weight:  32kg (transport case and accessories included)

Standard Configuration
6m self-sealing stainless steel armoured tube
DN8 self-sealing coupling
DN20 self-sealing coupling
5μm self-sealing rectangular filter
USB storage disk
Power cable
Operation manual
Calibration certificate

Optional accessories
3m self-sealing FEP sampling tube
6m self-sealing FEP Psampling tube
3m self-sealing stainless steel armoured sampling tube
6m self-sealing stainless steel armoured sampling tube

 